← Back to map

Residential · Vésenaz

Route de La-Capite 274

EGID 1007325 · Latest year: 2025 · La Pallanterie

762
IDC · MJ/m²·yr
787
3-year average
54
Estimated final energy · MWh
254
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
762
Peer median
384
Difference
+98.4 %
Percentile
99th
Zone median
—

Higher IDC than 99 % of similar buildings. Higher than the peer median — may warrant further assessment.

Peer group: Residential buildings across the canton of Geneva, 2025 (8340 buildings).

Zone comparison hidden: fewer than 10 buildings in this zone.

Trend

Not enough history for a 3-year comparison.

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredabove
  • 800 — significant (until 2026)below
  • 650 — significant (from 2027)above

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

0200400600800450201120122014201620242025
━ Building IDC╌ Peer median
Building type
Residential
Official use
Habitation un logement
Main energy carrier
Gas
Industrial zone
La Pallanterie

IDC × SRE, climate-normalised: heating and hot water only, not process energy.