← Back to map

Residential · Vernier

Route de Vernier 166

EGID 1028213 · Latest year: 2023 · ZIBAT

625
IDC · MJ/m²·yr
619
3-year average
43
Estimated thermal energy · MWh
245
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
625
Peer median
399
Difference
+56.6 %
Percentile
96th
Zone median
248 (+152.5 %)

Higher IDC than 96 % of similar buildings. Higher than the peer median — may warrant further assessment.

Peer group: Residential buildings across the canton of Geneva, 2023 (9840 buildings).

Trend

+17.3 %
Change over 3 years (2020 → 2023: 533 → 625)

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredabove
  • 800 — significant (until 2026)below
  • 650 — significant (from 2027)below

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

0200400600450202020222023
━ Building IDC╌ Peer median
Building type
Residential
Official use
Habitation un logement
Main energy carrier
Heat pump electricity (after 5 Aug 2010)
Industrial zone
ZIBAT

IDC × SRE, climate-normalised: heating and hot water only, not process energy.

For heat pumps the IDC counts electricity used, which lowers the value compared with fuel-based systems.