← Back to map

Offices · Vernier

Route de Vernier 132

EGID 1028752 · Latest year: 2024 · La Renfile

519
IDC · MJ/m²·yr
584
3-year average
50
Estimated thermal energy · MWh
345
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
519
Peer median
322
Difference
+61.2 %
Percentile
88th
Zone median
—

Higher IDC than 88 % of similar buildings. Higher than the peer median — may warrant further assessment.

Peer group: Offices buildings across the canton of Geneva, 2024 (740 buildings).

Zone comparison hidden: fewer than 10 buildings in this zone.

Trend

−12.3 %
Change over 3 years (2021 → 2024: 592 → 519)

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredabove
  • 800 — significant (until 2026)below
  • 650 — significant (from 2027)below

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

020040060080010001200140045020112012201420162018202020222024
━ Building IDC╌ Peer median
Building type
Offices
Official use
Bureaux
Main energy carrier
Heating oil
Industrial zone
La Renfile

IDC × SRE, climate-normalised: heating and hot water only, not process energy.