← Back to map

Retail & services · Carouge GE

Route de Saint-Julien 34

EGID 2034899 · Latest year: 2014 · PAV · Carouge

Outdated data: the last IDC declaration for this building dates from 2014. It is shown for reference but excluded from statistics.

759
IDC · MJ/m²·yr
768
3-year average
160
Estimated thermal energy · MWh
761
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
759
Peer median
520
Difference
+46.0 %
Percentile
87th
Zone median
489 (+55.2 %)

In 2014, higher IDC than 87 % of similar buildings. Higher than the peer median — may warrant further assessment.

Peer group: Retail & services buildings across the canton of Geneva, 2014 (415 buildings).

Trend

−1.9 %
Change over 3 years (2011 → 2014: 774 → 759)

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredabove
  • 800 — significant (until 2026)below
  • 650 — significant (from 2027)above

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

0200400600800450201120122014
━ Building IDC╌ Peer median
Building type
Retail & services
Official use
Commerce
Main energy carrier
Gas
Industrial zone
PAV · Carouge

IDC × SRE, climate-normalised: heating and hot water only, not process energy.