← Back to map

Industrial · Carouge GE

Avenue de la Praille 50

EGID 2034928 · Latest year: 2025 · PAV · Carouge (3)

411
IDC · MJ/m²·yr
403
3-year average
798
Estimated thermal energy · MWh
6'988
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
411
Peer median
318
Difference
+29.2 %
Percentile
74th
Zone median
—

Higher IDC than 74 % of similar buildings. Higher than the peer median — may warrant further assessment.

Peer group: Industrial buildings across the canton of Geneva, 2025 (333 buildings).

Zone comparison hidden: fewer than 10 buildings in this zone.

Trend

Not enough history for a 3-year comparison.

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredbelow
  • 800 — significant (until 2026)below
  • 650 — significant (from 2027)below

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

0100200300400500450202320242025
━ Building IDC╌ Peer median
Building type
Industrial
Official use
Atelier
Main energy carrier
Gas
Industrial zone
PAV · Carouge (3)

IDC × SRE, climate-normalised: heating and hot water only, not process energy.