← Back to map

Retail & services · Meyrin

Chemin de Riantbosson 12

EGID 2041280 · Latest year: 2025 · ZIRIAN

616
IDC · MJ/m²·yr
523
3-year average
273
Estimated thermal energy · MWh
1'595
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
616
Peer median
362
Difference
+70.2 %
Percentile
93rd
Zone median
—

Higher IDC than 93 % of similar buildings. Higher than the peer median — may warrant further assessment.

Peer group: Retail & services buildings across the canton of Geneva, 2025 (218 buildings).

Zone comparison hidden: fewer than 10 buildings in this zone.

Trend

+36.9 %
Change over 3 years (2022 → 2025: 450 → 616)

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredabove
  • 800 — significant (until 2026)below
  • 650 — significant (from 2027)below

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

0200400600450201120122014201620182020202220242025
━ Building IDC╌ Peer median
Building type
Retail & services
Official use
Commerce
Main energy carrier
Gas
Industrial zone
ZIRIAN

IDC × SRE, climate-normalised: heating and hot water only, not process energy.