← Back to map

Offices · Vernier

Chemin de Champs-Prévost 10

EGID 2043232 · Latest year: 2021 · ZIBAT

737
IDC · MJ/m²·yr
687
3-year average
13
Estimated thermal energy · MWh
64
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
737
Peer median
364
Difference
+102.5 %
Percentile
96th
Zone median
400 (+84.3 %)

Higher IDC than 96 % of similar buildings. Higher than the peer median — may warrant further assessment.

Peer group: Offices buildings across the canton of Geneva, 2021 (833 buildings).

Trend

+10.7 %
Change over 3 years (2018 → 2021: 666 → 737)

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredabove
  • 800 — significant (until 2026)below
  • 650 — significant (from 2027)above

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

020040060080010004502010201220142016201820202021
━ Building IDC╌ Peer median
Building type
Offices
Official use
Bureaux
Main energy carrier
Gas
Industrial zone
ZIBAT

IDC × SRE, climate-normalised: heating and hot water only, not process energy.