← Back to map

Mixed residential · Petit-Lancy

Route du Pont-BUTIN 14

EGID 295077737 · Latest year: 2015 · Pont-Butin

Outdated data: the last IDC declaration for this building dates from 2015. It is shown for reference but excluded from statistics.

378
IDC · MJ/m²·yr
382
3-year average
465
Estimated thermal energy · MWh
4'425
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
378
Peer median
496
Difference
−23.8 %
Percentile
14th
Zone median
343 (+10.2 %)

In 2015, higher IDC than 14 % of similar buildings. Lower than the peer median.

Peer group: Mixed residential buildings across the canton of Geneva, 2015 (4347 buildings).

Trend

+18.5 %
Change over 3 years (2012 → 2015: 319 → 378)

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredbelow
  • 800 — significant (until 2026)below
  • 650 — significant (from 2027)below

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

01002003004005006004502011201220142015
━ Building IDC╌ Peer median
Building type
Mixed residential
Official use
Habitation - activités
Main energy carrier
Heating oil
Industrial zone
Pont-Butin

IDC × SRE, climate-normalised: heating and hot water only, not process energy.