Logistics & storage · Carouge GE
Rue Antoine-JOLIVET 6
EGID 295100066 · Latest year: 2020 · PAV · Carouge (3)
588
IDC · MJ/m²·yr
558
3-year average
132
Estimated thermal energy · MWh
806
Heated floor area (SRE) · m²
Compared with similar buildings
050100
- IDC
- 588
- Peer median
- 477
- Difference
- +23.3 %
- Percentile
- 74th
- Zone median
- —
Higher IDC than 74 % of similar buildings. Higher than the peer median — may warrant further assessment.
Peer group: Logistics & storage buildings across the canton of Geneva, 2020 (127 buildings).
Zone comparison hidden: fewer than 10 buildings in this zone.
Trend
+2.8 %
Change over 3 years (2017 → 2020: 572 → 588)
Geneva legal thresholds (indicative)
Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).
- 450 — measures requiredabove
- 800 — significant (until 2026)below
- 650 — significant (from 2027)below
Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.
IDC history
- Building type
- Logistics & storage
- Official use
- Dépôt
- Main energy carrier
- Gas
- Industrial zone
- PAV · Carouge (3)
IDC × SRE, climate-normalised: heating and hot water only, not process energy.