← Back to map

Industrial · Meyrin

Route du Nant-d'Avril 146

EGID 2041322 · Latest year: 2018 · ZIMEYSA

Outdated data: the last IDC declaration for this building dates from 2018. It is shown for reference but excluded from statistics.

776
IDC · MJ/m²·yr
773
3-year average
4'674
Estimated thermal energy · MWh
21'683
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
776
Peer median
430
Difference
+80.7 %
Percentile
92nd
Zone median
450 (+72.4 %)

In 2018, higher IDC than 92 % of similar buildings. Higher than the peer median — may warrant further assessment.

Peer group: Industrial buildings across the canton of Geneva, 2018 (412 buildings).

Trend

−10.4 %
Change over 3 years (2015 → 2018: 866 → 776)

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredabove
  • 800 — significant (until 2026)below
  • 650 — significant (from 2027)above

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

0200400600800100045020112012201420162018
━ Building IDC╌ Peer median
Building type
Industrial
Official use
Usine
Main energy carrier
Gas
Industrial zone
ZIMEYSA

IDC × SRE, climate-normalised: heating and hot water only, not process energy.