← Back to map

Industrial · Meyrin

Route du Mandement 15

EGID 295085925 · Latest year: 2019 · ZIMEYSA

Outdated data: the last IDC declaration for this building dates from 2019. It is shown for reference but excluded from statistics.

815
IDC · MJ/m²·yr
844
3-year average
404
Estimated thermal energy · MWh
1'783
Heated floor area (SRE) · m²

Compared with similar buildings

050100
IDC
815
Peer median
422
Difference
+93.1 %
Percentile
94th
Zone median
396 (+105.8 %)

In 2019, higher IDC than 94 % of similar buildings. Higher than the peer median — may warrant further assessment.

Peer group: Industrial buildings across the canton of Geneva, 2019 (401 buildings).

Trend

−6.8 %
Change over 3 years (2016 → 2019: 874 → 815)

Geneva legal thresholds (indicative)

Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).

  • 450 — measures requiredabove
  • 800 — significant (until 2026)above
  • 650 — significant (from 2027)above

Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.

IDC history

0200400600800450201020122014201620182019
━ Building IDC╌ Peer median
Building type
Industrial
Official use
Atelier
Main energy carrier
Heating oil
Industrial zone
ZIMEYSA

IDC × SRE, climate-normalised: heating and hot water only, not process energy.