Rue Emma-KAMMACHER 6
EGID 295113301 · Latest year: 2015 · ZIMEYSA
Outdated data: the last IDC declaration for this building dates from 2015. It is shown for reference but excluded from statistics.
Compared with similar buildings
- IDC
- 218
- Peer median
- 424
- Difference
- −48.6 %
- Percentile
- 8th
- Zone median
- 419 (−47.9 %)
In 2015, higher IDC than 8 % of similar buildings. Lower than the peer median.
Peer group: Industrial buildings across the canton of Geneva, 2015 (453 buildings).
Trend
Geneva legal thresholds (indicative)
Geneva's energy regulation compares the 3-year average IDC with thresholds. Above 450 MJ/m², owners must take improvement measures; above the "significant" threshold, energy renovation is mandatory (800 until 2026, 650 from 2027, 550 from 2031).
- 450 — measures requiredbelow
- 800 — significant (until 2026)below
- 650 — significant (from 2027)below
Indicative reading based on published data. Only the cantonal energy office (OCEN) determines obligations.
IDC history
- Building type
- Industrial
- Official use
- Atelier
- Main energy carrier
- Heat pump electricity (before 5 Aug 2010)
- Industrial zone
- ZIMEYSA
IDC × SRE, climate-normalised: heating and hot water only, not process energy.
For heat pumps the IDC counts electricity used, which lowers the value compared with fuel-based systems.